Air Cooled Chiller/Heat Pump (KAW050GR)
![]() Air Cooled Chiller/Heat Pump (KAW050GR) |
Product Description
Modular air cooled chiller/heat pump, adopt environment friendly refrigerant R407c, approved by CE. Flexible output by combining numbers of basic unit.
Standard cooling conditions: Return water temperature 12º C, outlet water temperature 7º C, ambient temperature 35º C;
Standard heating conditions: Return water temperature 40º C, outlet water temperature 45º C, ambient temperature 7º C.
Manufacturer tests the noise level showed above in lab. The noise level of installed unit could be different with above data due to the surrounding condition.
Manufacturer keeps the right to change technical data due to technical improvement.
| Model No. KAW- | 050GR | 100GR | 150GR | 200GR | 250GR | 300GR | 350GR | 400GR | |
| Standard cooling capacity | kW | 49.5 | 99 | 148.5 | 198 | 247.5 | 297 | 346.5 | 396 |
| kCal/h | 42562 | 85125 | 127687 | 170249 | 212812 | 255374 | 297936 | 340499 | |
| Cooling capacity | kW | 19.7 | 39.4 | 59.1 | 78.8 | 98.5 | 118.2 | 137.9 | 157.6 |
| Standard heating capacity | kW | 58.3 | 116.6 | 174.9 | 233.2 | 291.5 | 349.8 | 408.1 | 466.4 |
| kCal/h | 50129 | 100258 | 150387 | 200516 | 250645 | 300774 | 350903 | 401032 | |
| Heating capacity | kW | 22.3 | 44.6 | 66.9 | 89.2 | 111.5 | 133.8 | 156.1 | 178.4 |
| Power source | 380 V/3N ~ /50Hz | ||||||||
| Compressor | Type | Horizontal multilevel centrifugal | |||||||
| units | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | |
| power(kW) | 8.75*2 | 8.75*4 | 8.75*6 | 8.75*8 | 8.75*10 | 8.75*12 | 8.75*14 | 8.75*16 | |
| Charged refrigerant | 1# | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 |
| R407C(kg) | 2# | 10.5 | 21 | 31.5 | 42 | 52.5 | 63 | 73.5 | 84 |
| Standard water flow | m3/h | 9.46 | 18.92 | 28.38 | 37.84 | 47.3 | 56.76 | 66.22 | 75.68 |
| Water pressure drop | kPa | 10.1 | 10.1 | 10.1 | 10.1 | 10.1 | 10.1 | 10.1 | 10.1 |
| Fan | Type | Low noise axial fan | |||||||
| Units | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | |
| Power(kW) | 0.75x2 | 0.75x4 | 0.75x6 | 0.75x8 | 0.75x10 | 0.75x12 | 0.75x14 | 0.75x16 | |
| Heat exchanger | Type | Shell-tube heat exchanger | |||||||
| Connection pipe | DN100 | DN125 | |||||||
| Figure dimension | Length(mm) | 2206 | |||||||
| Broad(mm) | 1112 | 2144 | 3176 | 4208 | 5240 | 6272 | 7304 | 8336 | |
| Height(mm) | 2090 | ||||||||
| weight | kg | 930 | 1860 | 2790 | 3720 | 4650 | 5580 | 6510 | 7440 |
| Pipe system | Same circle length | ||||||||
More Product Features
| Model NO.: | KAW050GR |
| Standard: | CE |
| Company: | Hanko Electronic Co., Ltd. |
Other products from this company
Most Popular
-

Temperature Controller Input: Thermocouple K, E. S Thermal resistance: ... -

Patio Heater (HSS-RS-PC\SS\SH) Patio Heater with Height of 2, 210mm, Available ... -

R410a Heat Pump Water Heater (AW12 AW13 AW15) Heating and domestic hot water; Suitable for ...
-

Air Conditioner & Water Heater Our Air Conditioner & Water Heater systems with ... -

KLV Motorized Valve KLV motorized valve is composed of two parts with ... -

Air Cooled Water Chiller (Module Type) LAW (Modular type Air Cooled Water chillers and ...
-

Room Thermostat (TR-007) Heating/cooling mode Fan speed: High/middle ... -

Floor Heating Thermostat (AE-508) AE-P508-A and AE-P508-F electric thermostat are ... -

Inside Value Type Stainless Steel Water Separator (KOP010) Technical Parameter Branch pipeline quantity: ...
-

Fireplace Heater CIE-B I 1850w, 220V, 50/60HZ. -

Fan Coil Unit Fan Coil Unit Compact, lightweight design ... -

Room Thermostat / Weekly Programmable Room (DC80) The DC80...Is used for 2-position control with ...
-

Infrared Thermometer SPECIFICATIONS TEMPERATURE RANGE: -20º C ... -

Spring Style and Band Heating Elements (SC-45) 1) Material: Steel, stainless steel, mica or ... -

Climatic Testing Chamber (C, 180, -40 ECO) Standard Chamber Features 1 shelf 1 year ...
Quick Products |
Inquiry Basket (